Heat-Insulating EVA Film
Heat-Insulating EVA Film
1、Transparency Grade:HT (High Transparency)
2、Product Thickness: 0.38mm - 0.76mm
3、Length: 50m - 100m
4、Width: 2500mm
5、Material: Ethylene-vinyl acetate copolymer, no recycled content
Why Choose EVA-Insul-HT?
- Energy-Saving & Heat-Insulating: Effectively blocks infrared radiation to reduce indoor heat and lower cooling costs.
- High Transparency: Maintains crystal-clear visibility without haze or color distortion.
- UV Protection: Blocks over 99% of UV rays, protecting interiors and printed surfaces from fading.
- Strong Adhesion & Safety: Offers excellent glass bonding and fragment retention for enhanced safety.
- Environmentally Friendly: Made with high-purity EVA copolymer, free from recycled materials.
Application Scope
- Sunroom Insulating Glass: Keeps interiors cool and bright by reducing solar heat gain.
- Advertising Machine Panels: Protects displays from UV damage while ensuring vivid image visibility.
- Energy-Saving Laminated Glass: Enhances building insulation performance and occupant comfort.
- Architectural Glazing & Facades: Provides superior clarity and long-lasting adhesion in outdoor environments.
Technical Specifications
| Model | Thickness (mm) | Width (mm) | Roll Length (m) | Packaging Specifications |
|---|---|---|---|---|
| EVA-insul-HT380 | 0.38 | 2500 | 100 | Vacuum bag + shockproof film + composite kraft paper (Optional extra plywood case) |
| EVA-insul-HT760 | 0.76 | 2500 | 50 |
Product Performance Parameters
| Test item | EVA-insul-HT |
|---|---|
| Visible light transmittance % | 4mm+0.76+4mm Laminated glass: >70.0 |
| Shading coefficient | <0.64 |
| Heat transfer coefficient W/(M2*K) | <5.5 |
| Direct transmittance of sunlight % | <45.0 |
| Direct sunlight reflection ratio % | <6.0 |
| Haze % | 0.76mm:<0.60 1.52mm:<0.95 |
| UV blocked rate % | 0.76mm: >99 1.52mm: >99 |
| Infrared blocked rate % | 0.76mm: >85 1.52mm: >95 |
| Tensile strength MPa | >25 |
| Adhesion with glass (N/CM) | >85 |
| Cross-linking rate % | >85 |
Note:the information and relevant data listed in this article are established in the laboratory of the company's technical department,and their contents are correct based on the truth. However, we will not make any statement or guarantee on the integrity or accuracy of the listed information and data.We provide the content of this article on the condition that it is for the user's reference only,and before using it,decide whether the information and data are suitable for their own purpose of use.In no event shall we be liable or liable for damages of any nature whatsoever arising out of the use of or reliance on the content of this document or the products mentioned herein.